4 MOUNTING AND INSTALLATION COD: 100M12/24.B.2021
EN
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
23
Low pressure
connections
max 3 bar
Connection between seawater intake mesh
filter non-return valve inlet pump group
Armorvin reinforced pipe PN6
with 20 mm internal diameter
Connection between the discharge of the
watermaker through hull discharge fittings of
the vessel
Armorvin reinforced pipe PN6
with 16 mm internal diameter
Medium pressure
connections
max 13 bar
Connections fresh water pressurized system
carbon filter-backflow valve outletpump inlet
Connections pump outlet-5 microns filter
watermaker inlet.
Rubber reinforced pipe PN 16
minimum, internal diameter
20 mm.
Low pressure
connections -
max 3 bar
Watermaker - fresh water tank
¼’’ fittings, Small plastic blue
pipe 6x8mm provided within
the scope of supply
PUMP CONNECTIONS:
Connect the in/out pipe to the pump as follows:
PUMP IN AND OUT
FIG. 4-2
CAUTION
The pump has to be placed as close as possible to the seawater intake and as low as
possible respect to the seawater level; furthermore, it is recommended to avoid long and
convoluted path of the connection hoses.
ATTENTION
The use of an improper pipe can cause a break which prevent the security of the vessel.