6.7 Periodic maintenance
6.7.1 Membrane replacement
Reverse osmosis membranes have an average lifetime of about 7 years If correctly maintained. It is anyway
recommended to check the efficiency of the membranes after 5 years of functioning and verify the needed of
a replacement. Please, refer to a certified Schenker service centre for this operation.
6.8 Adjustments
Accumulator
It is a reservoir of air that has the function of damping the
pressure oscillations during the commutations of the
watermaker. The accumulator is factory loaded at a pressure
of about 6 bar. The charge level must be periodically checked
in order to guarantee a correct functioning to the watermaker.
On some versions it might be installed on the unit.