5 FUNCTIONING AND USE COD: 100M12/24.B.2021
EN
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
31
5.3.2 Normal operating procedure with final flushing (recommended procedure)
1. Push ON/OFF to start the watermaker.
2. Push FLUSHING to flush and stop the
watermaker. The watermaker will activate a
flushing cycle then it will stop itself after 1 minute.
5.3.3 Working cycle with timer
1. Keep ON/OFF pressed for a while, then you
will hear 1-2-3-beeps. Once released ON/OFF
the watermaker will work for 1-2-3 hours then
will flush and will stop.
2. The unit can be stopped at any time by
pushing the ON/OFF button (without final
flushing) or the FLUSHING button (with final
flushing).
5.3.4 Long flushing procedure
1. Push FLUSHING. A 3-minute flushing
procedure with fresh water will start. Both
ON/OFF and FLUSHING buttonslights will be
on.
2. The unit can be stopped at any time by pushing
the ON/OFF button

Table of Contents