7 –TROUBLESHOOTING COD.30Z12/24.B.2021
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
42
7. TROUBLESHOOTING
7.1 Troubleshooting chart
Start the pump and the
electrovalve using microswitches.
Pump starts but the system
suddenly blocks in high pressure
Hydraulic block
Dirty filters
Perform reset procedure
Replace filters
High pressure variations during
commutation
(> 0,2 Bar)
Low pressure in the accumulator
Load at a pressure of about 4 bar
Low production / normal or low
pressure
Low battery
Air within the system
Check battery charge
Purge air by opening for a while
the pressure valve
Low production / high pressure
(> 9 Bar)
Clogged filters
Clogged membranes
Cold seawater
Replace filters
Perform washing with SC1
Normal condition