EasyManua.ls Logo

Scheppach HCE3200i

Scheppach HCE3200i
56 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
24
|
GB
13. Possible causes of failure
Troubleshooting Cause Remedy
Device does not work
No electrical voltage at the
device.
Check the fuse, power cable and power plug and
have them replaced by qualied personnel if nec-
essary.
Cross section of the extension
cable not large enough and/or
the extension cable is too long.
Use extension cables with larger cross sections
and/or use shorter extension cables.
The mains voltage is lower than
that specied.
Contact the power supply company if necessary.
The pump is frozen. Check and thaw if necessary.
The motor starts but there
is no build up of pressure
Air intake in the water inlet.
Check the supply hose and hose connection and
replace if necessary.
Discharge nozzle is too large. Check and replace if necessary.
Irregular operating pres-
sure
Air intake in the water inlet.
Check the supply hose and hose connection and
replace if necessary.

Table of Contents

Related product manuals