Putting in oil (Fig. 5)
Do not tilt the generator when topping up engine oil. This could lead to overlling and damage to the
engine.
1. Place the generator on a at surface.
2. Remove the screws and the cover (5).
3. Unscrew the oil ller plug (17).
4. Pour in 0.28 litres of engine oil (15W-40).
5. Close the cover (5) and tighten the screws.
Putting in fuel (Fig. 1/8)
m DANGER
Keep away from ignition sources! Always refuel in well-ventilated rooms or outside. Allow the gener-
ator to cool down for at least 2 minutes before removing the tank cover. Slowly loosen the cover to
release the pressure in the tank. Open the fuel tank cap (2) and, using a ller pipe (not included in
delivery), pour in a maximum of 3 litres of unleaded fuel into the fuel container. Ensure the tank level
is not exceeded and no fuel is spilled. Use the fuel lter. Clean up spilled fuel immediately and wait
until the fuel fumes have evaporated (re hazard). Close the fuel tank cap (2).
8. Operation
Start the engine (Fig. )
ATTENTION! When starting with the starter grip (6) you can injure your hand with the sudden kick
back.
Wear protective gloves when starting.
In „warm“ condition
Put the on / o󰀨 switch (10) to the “on” position.
Rotate the fuel valve (9) to the “ON” position.
Start the engine with the starter grip (6) by sharply pulling the handle. If the engine has not start-
ed pull the handle again.
In „cold“ condition
Put the on / o󰀨 switch (10) to the “on” position.
Pull out the choke lever (11). (not needed when warm)
Rotate the fuel valve (9) to the “ON” position.
Start the engine with the starter grip (6) by sharply pulling the handle. If the engine has not start-
ed pull the handle again.
Push the choke lever (11) back once the engine has started.
ATTENTION! This socket can be loaded continuously (S1) with 1000 W and short term (S2) for a
maximum of 5 seconds with 1200 W. Note: Some electric devices (sabre saws, drills etc.) can use
more electricity when doing heavy duty tasks.
Storing the engine (Fig. 1)
Before putting away, let the generator run without load so that the device can „cool down“.
Turn the on / o󰀨 switch (10) to the „OFF“ position.
Close the petrol tap (9).