1
GENERAL BATTERY SAFETY
1. Before you use your battery charger, be sure to read all
instructions and cautions printed on:
• Battery Charger
• Battery
• Vehicle or unit using battery
2. Use battery charger on LEAD ACID type rechargeable batter-
ies only, such as used in autos, trucks, tractors, airplanes,
vans, RV's trolling motors, etc. Charger is not intended to sup-
ply power to low-voltage electrical system other than in an
automotive application.
WARNING: Do not use battery charger for charging dry-cell
batteries that are commonly used with home appliances.
These batteries may burst and cause injury to persons and
damage to property.
3. Use only attachments recommended or sold by manufacturer.
Use of non-recommended attachments may result in fire, elec-
tric shock, or injury.
4. When disconnecting the battery charger, pull by the plug not
by the cord. Pulling on the cord may cause damage to cord or
plug.
5. Locate battery power cord so it cannot be stepped on, tripped
over, or subjected to damage or stress.
6. Do not operate charger with damaged cord or plug. Have cord
replaced immediately.
7. Do not operate charger if it has received a sharp blow, been
dropped, or otherwise damaged in any way. Take it to a quali-
fied professional for inspection and repair.
8. Do not disassemble charger. Take it to a qualified professional
when service or repair is required. Incorrect reassembly may
result in electric shock or fire.
9. To reduce risk of electric shock, unplug charger from outlet
before attempting any maintenance or cleaning.
10. Do not use an extension cord unless absolutely neces-
sary. Use of an improper extension cord could result in fire
or electric shock. If an extension cord must be used, make
sure that:
• Pins on plug of extension cord are the same number, size,
and shape as those of plug on charger.
• Extension cord is properly wired and in good electrical con-
dition.
• Wire size is large enough for AC ampere rating of charger,
as specified below:
_____________________________________________
Length of cord (feet): 25 50 100 150
AWG size of cord: 18 18 18 16
_____________________________________________
11. Always charge battery in a well ventilated area.
NEVER operate in a closed-in or restricted area without ad-
equate ventilation.
WARNING: Risk of explosive gas.
12. Locate charger as far away from battery as DC charger cables
permit.
13. Do not expose charger to rain or snow.
14. NEVER charge a frozen battery. If battery fluid (electrolyte) is
frozen, bring into a warm area to thaw before charging.
15. NEVER allow battery acid to drip on charger when reading
specific gravity or filling battery.
16. NEVER set a battery on top of charger.
17. NEVER place charger directly above battery being charged.
Gases from battery will corrode and damage charger.
18. NEVER touch the battery clips together when the charger is
energized.
19. NEVER crank engine with charger attached to battery.
Read Rules for Safe Operation and Instructions Carefully
Working in vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal
battery operation. For this reason, it is of utmost importance that each time before using your charger, you
read this manual and follow the instructions exactly.
Owner's Manual
–Save–
Important Safety Instructions
WARNING: Handling the cord on this product or cords associated with accessories sold with this product, will expose you to lead, a chemical
known to the State of California to cause cancer and birth defects or other reproductive harm.
Wash hands after handling.
Battery
Charger
Models:
SE-82-6 & SE-3002
6 and 2 Amp
Battery Charger
For 6 and 12 Volt Batteries
SCHUMACHER ELECTRIC CORPORATION
801 BUSINESS CENTER DRIVE • MOUNT PROSPECT, ILLINOIS 60056-2179
Send Warranty Product Repairs to: 1025 E. Thompson, Hoopeston, IL 60942-0280
Call Customer Service if you have questions: 1-800-621-5485
00-00-000531/0103

Questions and Answers

  • J
    Jose TorresJul 30, 2025
    What to do if my Schumacher Battery Charger shows no meter reading?
    • L
      Lisa WhiteJul 30, 2025
      If your Schumacher Battery Charger displays no meter reading, here are a few things to check: * Ensure the connections aren't reversed; if they are, reverse the clips and reconnect, rocking them back and forth to ensure a solid connection. * Check for poor electrical connections. Clean the clips and battery poles, then reconnect, again rocking them to ensure they bite in. * Verify that the AC outlet is working by plugging in a lamp or another appliance. * Consider the possibility of a defective battery that won't accept a charge, and have it checked.
  • A
    Alex StuartAug 5, 2025
    What does a high meter reading on my Schumacher Battery Charger mean?
    • W
      wmartinAug 6, 2025
      A high meter reading on your Schumacher Battery Charger indicates that the battery is defective and will not take a charge. Have the battery checked.
  • J
    Jasmin PetersenAug 11, 2025
    Why is the charging current less than the full output rating on my Schumacher SE-3002?
    • J
      James BuckAug 12, 2025
      The charging current might be less than the full output rating of your Schumacher Battery Charger for several reasons: 1. The battery may already be partially charged; in this case, continue charging. 2. The battery could be defective, with crusted plates that prevent it from accepting a full charge; have it checked and replaced if necessary. 3. The AC power supply might be low; try plugging the charger into another grounded AC outlet.
  • K
    Kevin WilsonAug 17, 2025
    What to do if the ammeter needle moves to the extreme right and returns to zero with a clicking sound on my Schumacher SE-3002?
    • A
      Andrea SanchezAug 17, 2025
      If the ammeter needle on your Schumacher Battery Charger moves to the extreme right, quickly returns to zero, and is accompanied by a clicking sound, here’s what it could mean: * The battery is severely discharged but otherwise good. Allow charging to continue, the circuit breaker will cycle, and the needle will swing until the battery recovers sufficiently. * The battery is defective and won't accept a charge; have the battery checked. * The charger is cycling after a circuit-breaking overload. Wait for the charger to automatically reset itself.
  • S
    Scott RossAug 23, 2025
    Why won't my Schumacher Battery Charger taper down?
    • J
      Joseph LambAug 23, 2025
      The reason your Schumacher Battery Charger won't taper down is that the battery has a problem and will not take a full charge. Have the battery checked.

Summary

Important Safety Instructions

General Battery Safety

Essential safety guidelines for handling and using lead-acid batteries.

Personal Precautions and Safety

Ground and AC Power Cord Connections

Instructions on proper grounding methods for the charger and its connections.

Preparing to Charge

Battery Charger Controls

Charge Rate and Voltage Switch Settings

Guidance on selecting the correct charge rate and voltage for different batteries.

Ammeter and Percent of Charge

Understanding the ammeter and percentage indicators for charge status.

Reading Ammeter Readings

Circuit Breaker Operation

Battery Types Explained

Charging Battery in Vehicle

Charging Battery Out of Vehicle

Maintenance and Cleaning

Troubleshooting Common Issues

Limited Warranty Information

Schumacher SE-3002 Specifications

General IconGeneral
Output Voltage6V / 12V
Input Voltage120V AC
Input Frequency60Hz
Microprocessor ControlledYes
Float Mode MonitoringYes
Multi-Stage ChargingYes
Charge Rate2A
Battery TypeAGM, Gel
Protection FeaturesShort Circuit, Overload, Reverse Polarity