Assembly
22
08.00 | MPG-plus | Assembly and operating manual | en | 0389216
5.2.2 Pneumatic connection
Air connections
1 Main connections (Hose connection)
(A = open, B = close)
2 Hose-free direct connection at the base
(a = open, b = close)
Hose-free direct connection
3 Gripper 5 attachment part
4 O-ring
Ite
m
Mounting MPG-plus
16 20 25 32 40 50 64
1 Thread in main air connec-
tions
M2.5 M3 M3 M5 M5 M5 M5
Maximal screw-in depth
[mm]
2.5 3 3 4.5 5 5 5

Table of Contents