Questions and Answers

  • N
    Nancy GarciaAug 5, 2025
    What to do if the LED on SCHUNK MEG 64 EC controller flashes continuously (approx. 4 times every 1 sec.)?
    • S
      Samantha Madden MDAug 5, 2025
      If the LED on your SCHUNK Industrial Equipment controller flashes continuously about 4 times every second, it indicates an overcurrent warning. To resolve this, lower the gripping force set value.
  • G
    gutierrezsandraAug 9, 2025
    Why is the LED on my SCHUNK MEG 64 EC Industrial Equipment controller flashing continuously (approx. once per sec.)?
    • N
      npachecoAug 9, 2025
      If the LED on the SCHUNK Industrial Equipment controller flashes continuously approximately once per second, it could be due to the gripper not being connected or a cable breakage. Check the connection of the gripper to the controller, ensuring it is correctly connected. Also, check the coil resistances of the motor cables to each other; it should be around 8.2 Ohm.
  • P
    Pamela HartAug 13, 2025
    What causes the LED on SCHUNK MEG 64 EC controller to flash continuously (approx. once every 2 sec.)?
    • M
      Matthew BlakeAug 13, 2025
      If the LED on your SCHUNK Industrial Equipment controller flashes continuously about once every 2 seconds, it means the controller temperature is too high. Try lowering the gripping force set value and ensure the controller has sufficient cooling.
  • K
    kdeleonAug 18, 2025
    What to do if the LED on SCHUNK MEG 64 EC Industrial Equipment controller flashes continuously (approx. once every 4 sec.)?
    • S
      Sarah BaileyAug 18, 2025
      If the LED on the SCHUNK Industrial Equipment controller flashes continuously approximately once every 4 seconds, it indicates an under- or overvoltage issue. Check the power supply to the controller.
  • E
    Erin JonesAug 22, 2025
    What to do if the LED on SCHUNK Industrial Equipment does not light up after switching on?
    • B
      bfitzgeraldAug 22, 2025
      If the LED on the SCHUNK Industrial Equipment controller does not light up after switching on, it indicates there is no power supply. Check the power supply to the controller.
  • J
    James ArnoldAug 27, 2025
    How to fix a SCHUNK Industrial Equipment controller when the LED doesn't flash 6 times on startup?
    • B
      Brian McdowellAug 27, 2025
      If the LED on the SCHUNK Industrial Equipment controller does not flash 6 times briefly when switching on, it indicates there is no power supply. Check the power supply to the controller and avoid repeated switching off and on of the power supply.
  • B
    Brian CoxAug 31, 2025
    What to do if the LED on SCHUNK Industrial Equipment controller flashes continuously (approx. once per sec.) because fingers are mechanically jammed?
    • M
      Mrs. Donna TuckerAug 31, 2025
      If the LED on the SCHUNK Industrial Equipment controller flashes continuously approximately once per second, and the fingers are mechanically jammed, check whether the adapter plate is stepped, especially if it's a lateral attachment.