EasyManuals Logo

SCHUNK MEG 64 EC User Manual

Default Icon
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Maintenance
03.00 | MEG 50 EC | Assembly and Operating Manual | en | 389201
39
7 Maintenance
7.1 Maintenance intervals
Interval (million
cycles)
Maintenance work
1000 cycles
or once per day
Travel an entire stroke.
2
Treat all grease areas with lubricant,
Lubricate gripper [
}
40]
2
Clean all parts thoroughly, check for
damage and wear
For extreme ambient and application conditions, shortened
maintenance cycles can ensure the lifespan is maintained.
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
Reduce the lubricant intervals accordingly.
CAUTION
Damage to property caused by insufficient lubrication!
Continuously traveling short strokes when the product is
inadequately lubricated risks damaging it by causing it to run dry.
Travel the full stroke every 1000 cycles or at least once daily.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCHUNK MEG 64 EC and is the answer not in the manual?

SCHUNK MEG 64 EC Specifications

General IconGeneral
BrandSCHUNK
ModelMEG 64 EC
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals