  • C
    Curtis JimenezAug 11, 2025
    What to do if SCHUNK GWB module does not move?
    • K
      Kaitlin HouseAug 11, 2025
      If the SCHUNK Industrial Equipment module isn't moving, several factors could be at play. First, the base jaws might be jammed due to an uneven mounting surface; inspect the mounting surface and ensure it's sufficiently even. You can also try loosening the mounting screws and actuating the product again. Other potential causes include pressure dropping below the minimum required (check the air supply), switched compressed air lines (verify the connections), a defective or incorrectly set proximity switch (readjust or replace the sensor), open unused air connections (close them), a closed flow control valve (open it), a defective component (replace it or send it to SCHUNK for repair), or the aperture angle being limited to 0° (check the opening angle limitation).
  • L
    Lisa DanielsAug 21, 2025
    Why is the gripping force dropping in my SCHUNK GWB?
    • S
      Stephanie HoganAug 21, 2025
      If the gripping force of your SCHUNK Industrial Equipment is dropping, it could be due to several reasons. Firstly, compressed air might be escaping. Check the seals and replace them if necessary after disassembling the product. Another cause might be excessive grease in the mechanical movement space; in this case, clean and lubricate the product. Also, ensure that the pressure isn't dropping below the minimum required; verify the air supply. Finally, a defective component could be the culprit; consider replacing the component or sending it to SCHUNK for repair.
  • J
    Jillian GonzalesAug 31, 2025
    How to fix abrupt opening/closing of SCHUNK Industrial Equipment module?
    • R
      Richard MasonAug 31, 2025
      If your SCHUNK Industrial Equipment module is opening or closing abruptly, the issue might stem from a missing or incorrectly adjusted one-way flow control valve; install and adjust it properly. Alternatively, the loading might be too large; check the permissible weight and length of the gripper fingers.