Troubleshooting
32
02.00 | GWB | Assembly and Operating Manual | en | 389122
5.4 Opening angle not correct?
Possible cause Corrective action
The aperture angle is limited to 0°. Check opening angle limitation.
Pressure drops below minimum. Check air supply.
Pneumatic connection [
}
23]
5.5 Gripper opens or closes too slowly?
Possible cause Corrective action
One-way flow control valve is missing or
adjustet incorrectly.
Install and adjust one-way flow control
valve. Pneumatic connection [
}
23]