EasyManua.ls Logo

SCHUNK GWB Series - 6 Maintenance; Notes; Maintenance and Lubrication Intervals; Lubricants;Lubrication Points (Basic Lubrication)

SCHUNK GWB Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
02.00 | GWB | Assembly and Operating Manual | en | 389122
33
6 Maintenance
6.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
6.2 Maintenance and lubrication intervals
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
Reduce the lubricant intervals accordingly.
Maintenance- and lubrication interval
Size GWB 34 - 100
Interval [Mio. cycles] 2
6.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point Lubricant
Metallic sliding surfaces Molykote BR 2 plus
All seals Renolit HLT 2
Bore hole at the piston Renolit HLT 2

Table of Contents

Other manuals for SCHUNK GWB Series

Related product manuals