Start-up
03.00 | MEG 64 EC | Assembly and Operating Manual | en | 389203
25
MEG C
1 "Status" LED 3 Speed (P2)
2 Position (P3) 4 Force (P1)
The MEG C external controller for actuating the MEG EC gripper
has three potentiometers:
P1: Adjusting the gripping force
P2: Adjusting the gripping speed
P3: Adjusting the traverse path / the position (incremental input
of the relative value)
Each potentiometer is assigned a measuring jack, on which the
voltage set can be tapped for measuring.
The "Status" LED provides information about possible operating
statuses of the controller and about problems in the event of a
malfunction. The possible causes for malfunctions that can be
displayed by the Status LED are listed in the chapter on Problem
Analysis.
The MEG C controller (terminals 1, 3, 7, 9) is connected via a 4-pin
control cable on the X2 device plug of the MEG EC gripper. We
offer prefabricated control cables for this purpose ( accessories
in the catalog).