5.3.5 Mounting the magnetic switch MMS 22-IOL
CAUTION
Risk of damage to the sensor during assembly!
Observe the maximal tightening torque.
5.3.5.1 Size MPG-plus 25 – 50
For these sizes, there is a bracket in vertical direction mounted
standardly.
Ø Loosen the screws at the bracket.
Ø Move the sensor into to the bracket up to the stop.
Ø Tighten the screws at the bracket.
Ø Fasten the senor using a threaded pin.
Tightening torque: 10 Ncm
Ø Check the protrusion of sensor L1, see table "adjustment
dimension".
Ø Adjust the sensor, see assembly and operating manual of the
sensor.
Protrusion of the sensor to be mounted
Adjustment dimensions
Size L1 [mm] Size L1 [mm]
MPG-plus 25 8.8 MPG-plus 40 4.8
MPG-plus 25-AS -4.0 MPG-plus 40-AS 2.9
MPG-plus 25-IS 7.8 MPG-plus 40-IS -17.8
MPG-plus 32 5.5 MPG-plus 50 4.3
MPG-plus 32-AS -4.0 MPG-plus 50-AS -2.2
MPG-plus 32-IS 1.7 MPG-plus 50-IS -14.8