Assembly
13.00 | MPG-plus | Assembly and operating manual | en | 389216
33
5.3.7 Mounting the programmable magnetic switch MMS-P 22
CAUTION
Risk of damage to the sensor during assembly!
Observe the maximal tightening torque.
5.3.7.1 Size MPG-plus 25 – 50
For these sizes, there is a bracket in vertical direction mounted
standardly.
Ø If the sensor in horizontal direction is needed, turn and fasten
the bracket.
Ø Move the sensor into the bracket up to the stop.
OR: If there is no stop, adjust the L1 or L2 protrusion of the
sensor (see table "adjustment dimensions").
Ø Fasten the senor using a threaded pin.
Tightening torque: 10 Ncm
Ø Adjust the sensor, see assembly and operating manual of the
sensor.