3-6. ENGINE/FUSELAGE FIRE, OR FIRE OF UNDETERMINED
ORIGIN, IN FLIGHT - LOW/CRUISE ALTITUDE
Note:
If a fire is observed during flight, prevailing conditions such
as day/night, altitude, and available landing areas must be
considered in order to determine whether to execute a power-on or
power-off landing.
Power-on landing:

Maintain airspeed and rotor RPM; be prepared to perform a full
autorotation at any point in the approach.

Immediately perform power-on landing to suitable area.

If time permits:

Set battery switch in OFF position.
 Set generator switch in OFF position.

Upon landing:

Close throttle.

Set fuel shutoff valve in CLOSED position.

Exit aircraft with fire extinguisher.
Power-off landing:

Close throttle.

Immediately enter autorotation.

If time permits:

Set fuel shutoff valve in CLOSED position.

Set battery switch in OFF position.

Set generator switch in OFF position.
Emergency Procedures