7-26. BATTERY SERVICING AND MAINTENANCE (LEAD ACID
AND OPTIONAL NI-CAD BATTERIES)
Verify that BATTERY switch is OFF before servicing battery.
Perform battery servicing and maintenance according to
manufacturer’s instructions, in conjunction with removal/installation,
inspection and cleaning p rocedures in HMI.
To be performed by qualified maintenance personnel for Ni-Cad
Battery.
7-27. ACCESS AND INSPECTION PROVISIONS
CAUTION
Anytime maintenance work is to be performed near engine air
and engine cooling air inlets, use care to prevent entry of
foreign objects that might later be sucked into compressor or
cooling air blower. Place protective covers over engine inlet
screens. Covers should not be removed until work is complete
and debris is thoroughly cleaned out of the area.
Removable/hinged access doors and panels are provided in the
helicopter for servicing, inspection, removal, installation and
adjustment of components.
Locations of access and inspection provisions are shown in Fig. 7-6.
Areas, components and items accessible through the locations shown
in Fig. 7-6 are listed in Table 7-3.
Screws are used to secure access panels in stress areas.
Methods for removal and installation are obvious for doors and
panels.
Table 7-3. Access and Inspection Provisions Information
NOTE:
Refer to Fig. 7-6 for location of listed doors and panels.
Handling, Servicing & Maint.
Schweizer RSG, LLC.
Model 269D Helicopter
Pilot's Flight Manual
7-33
Reissued: 16 Jan 2019
Book 3.indd 195 8/4/19 1:25 PM

Table of Contents