F2- Detailed Programming Guide
User Settings
To enter the programming mode
* Master code #
999999 is the default factory master code
To exit from the programming mode
*
Note that to undertake the following programming
the master user must be logged in
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
3
0
#
Entry is by card only
3
1
#
Entry is by card and PIN together
3
2
#
Entry is by either card or PIN (default)
To add a user in either card or PIN mode, i.e. in the 3 2 # mode.
(Default setting)
To add a PIN user
1 User ID number # PIN # The ID number is any
number between 1 & 100. The PIN is any four
digits between 0000 & 9999 with the exception
of 1234 which is reserved. Users can be added
continuously without exiting programming mode
as follows: 1 User ID no 1 # PIN # User ID no 2
# PIN #
To delete a PIN user
2 User ID number # Users can be deleted conti-
nuously without exiting programming mode
To change the PIN of a PIN user
(This step must be done out of
programming mode)
* ID number # Old PIN # New PIN #
New PIN #
To add a card user (Method 1) This is
the fastest way to enter cards, user
ID number auto generation.
1 Read card # Cards can be added continuously
without exiting programming mode
To add a card user (Method 2) This
is the alternative way to enter cards
using user ID Allocation. In this
method a user ID is allocated to a
card. Only one user ID can be
allocated to a single card.
1 ID number # Read card # User can be added
continuously without exiting programming mode