8.3 Generating set identification
The generating set's identification plate is affixed inside one of the skirts or on the chassis.
Example of an identification plate
(B): CE/GOST marking
(if applicable)
(C): Guaranteed acoustic
power level
Serial numbers will be required when requesting troubleshooting advice or spare parts.
For your records, please enter the generating set and engine serial numbers below.
Generating set serial number:……../………….. - ……..……..….…. - ………
Engine make:………………………………………..
Engine serial number:……………………………………….. (e.g. Kohler (SERIAL NO. 4001200908))
8.4 Specifications
DIESEL 6000 E
SILENCE AVR
DIESEL 6500 TE
SILENCE AVR
Acoustic measurement
uncertainty
2P+T 230V 10/16A -
2P+T 230V 16A - 2P+T
230V 32A
2P+T 230V 10/16A -
2P+T 230V 16A - 2P+T
230V 32A
2P+T 230V 10/16A -
2P+T 230V 16A -
3P+T+N 400V 16A
2P+T 230V 10/16A -
2P+T 230V 16A -
3P+T+N 400V 16A
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
8.5 Recommended fuel quality
Using fuel which does not comply with the following specifications exposes the equipment to irreversible damage not covered under
warranty:
- Cleanliness and quality: make sure the diesel used does not contain water, that it is new and clean (not out of date or
contaminated).
- Specifications: ASTM D975 - 1D or 2D, EN590 or equivalent.
- Outdoor temperature below 0°C: use a special fuel (for more information, please contact one of our agents).