8.3 Generating set identification
The generating set's identification plate is affixed inside one of the skirts or on the chassis.
Example of an identification plate
(A): Model
(H): Current amperage
(B): CE/GOST marking
(if applicable)
(I): Current frequency
(C): Guaranteed acoustic
power level
(J): Current voltage
(D): Maximum power
(K): Protection rating
(E): Rated power
(L): Reference standard
(F): Power factor
(M): Serial number
(G): Earth
Serial numbers will be required when requesting troubleshooting advice or spare parts.
For your records, please enter the generating set and engine serial numbers below.
Generating set serial number:……../………….. - ……..……..….…. - ………
Engine make:………………………………………..
Engine serial number:……………………………………….. (e.g. Kohler (SERIAL NO. 4001200908))
8.4 Specifications
Model
DIESEL 6000 E
SILENCE
DIESEL 6000 E
SILENCE AVR
DIESEL 6500 TE
SILENCE
DIESEL 6500 TE
SILENCE AVR
Maximum power
5200 W
5200 W
5200 W
5200 W
Rated power
4160 W
4160 W
4160 W
4160 W
Acoustic pressure at 1 m
76 dB(A)
76 dB(A)
76 dB(A)
76 dB(A)
Acoustic measurement
uncertainty
1,3 dB(A)
1,3 dB(A)
1,3 dB(A)
1,3 dB(A)
Engine type
KOHLER KD440E
KOHLER KD440E
KOHLER KD440E
KOHLER KD440E
Recommended fuel
Diesel
Diesel
Diesel
Diesel
Fuel tank capacity
27 L
27 L
27 L
27 L
Recommended oil
SAE 5W40
SAE 5W40
SAE 5W40
SAE 5W40
Oil sump capacity
1,5 L
1,5 L
1,5 L
1,5 L
Oil cut-out*
o
o
o
o
Direct current
X
X
X
X
Alternating current
230V - 18,1A
230V - 18,1A
230V - 10A / 400V - 6A
230V - 10A / 400V - 6A
Circuit breaker(s)**
o
o
o
o
Socket type
2P+T 230V 10/16A -
2P+T 230V 16A - 2P+T
230V 32A
2P+T 230V 10/16A -
2P+T 230V 16A - 2P+T
230V 32A
2P+T 230V 10/16A -
2P+T 230V 16A -
3P+T+N 400V 16A
2P+T 230V 10/16A -
2P+T 230V 16A -
3P+T+N 400V 16A
Battery
12V - 50Ah - 450A (EN)
12V - 50Ah - 450A (EN)
12V - 50Ah - 450A (EN)
12V - 50Ah - 450A (EN)
Dimensions l x w x h
99 x 61,5 x 96 cm
99 x 61,5 x 96 cm
99 x 61,5 x 96 cm
99 x 61,5 x 96 cm
Weight (without fuel)
198 kg
215,5 kg
215,5 kg
215,5 kg
o: in series
X: not applicable
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
8.5 Recommended fuel quality
Using fuel which does not comply with the following specifications exposes the equipment to irreversible damage not covered under
warranty:
- Cleanliness and quality: make sure the diesel used does not contain water, that it is new and clean (not out of date or
contaminated).
- Specifications: ASTM D975 - 1D or 2D, EN590 or equivalent.
- Outdoor temperature below 0°C: use a special fuel (for more information, please contact one of our agents).