9. Troubleshooting
Load connected to the generating set during start-up.
Start and Stop control (fig. A - No. 9) on “O” or “OFF”.
Set the Start and Stop control to “I” or “ON”.
Check the oil level and top up if necessary
(see § Checking the oil level).
Change the fuel (see § Specifications).
Fill up with fuel (see § Filling with fuel).
Engine fuel tap (fig. A - no. 6) closed.
Open the engine fuel tap.
Air filter (fig. A - no. 7) clogged.
Clean the air filter (see § Cleaning the air filter).
Defective spark plug (fig. F - No. 2).
Check the spark plug (see § Checking the spark plug)
and replace if necessary.
Fuel supply blocked or leaking.
Have it checked, repaired or replaced.*
Check the oil level and fill-up if necessary
(see § Checking the oil level).
Fill up with fuel (see § Filling with fuel).
Blocked ventilation inlets.
Clean the generating set (see § Cleaning the
generating set).
Circuit breakers (fig. A - No. 11) not actuated.
Actuate the circuit breakers.
Defective appliance supply cord.
Defective electrical sockets (fig. A - No. 12).
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Triggering of
circuit breakers
Device connected or faulty cord.
Disconnect the device and the cord.
Overload (see § Capacity of the generating set).
* Operation(s) to be entrusted to one of our agents.