USER 1 24V DG MAXI
41121 REV.   1/21
 CTC CT T  D T D 
nlis
International registered trademark n. 804888
SEA S.p.A.
ona Indstriale Sant Atto  42  eramo  IA
elephone   1 41  a   1 44
.seateam.com
seacomseateam.com

Questions and Answers:

SEA USER 1 - 24V DG MAXI Specifications

General IconGeneral
BrandSEA
ModelUSER 1 - 24V DG MAXI
CategoryControl Unit
LanguageEnglish

Summary

1 - COMPONENTS

2 - CONNECTIONS

4 - CONNECTIONS ON CN1

Details on connecting devices to the CN1 terminal block for various inputs.

5 - CONNECTIONS ON CN2 and CN3

Explains connections for pre-wired and non-pre-wired limit switches.

6 - CONNECTIONS ON CN4

6.1 - MASTER/SLAVE CIRCUITS

Information on configuring two operators in a Master/Slave setup.

10 - CONNECTIONS ON CN8

11.1 - «SEM 2» MANAGEMENT UNIT CONNECTIONS

Details on connecting the SEM 2 management unit via the EXP connector.

12 - CONNECTIONS ON CNE

12.1 - ENCODER CONNECTION

How to connect the encoder to the CNE terminal for precise movement control.

13.1 - «I/O SURGE PROTECTOR» CIRCUIT CONNECTION

Connecting the surge protector to safeguard inputs and power supply.

14 - PRELIMINARY

14.1 - BASIC PROGRAMMING MENU AND SPECIAL MENU

Overview of accessing basic and special menus for configuration.

15 - BASIC MENU FUNCTIONS

1 - LANGUAGE

Allows selection of the user interface language for the control unit.

2 - TRANSMITTERS

Manages radio transmitter programming and functions.

3 - MOTOR

Configuration of motor type and related parameters.

16 - WORKING TIMES SELF-LEARNING

16.1 - QUICK SELF-LEARNING PROCEDURE

Expedited procedure to learn gate operational times without full setup.

17 - OPERATING LOGICS

AUTOMATIC LOGIC

Gate opens with first start, reverses on closing with start.

SAFETY LOGIC

Gate opens with first start, reverses on opening/closing with start.

DEAD MAN LOGIC

Gate operates only while the start button is held pressed.

18 - PASSWORD MANAGEMENT

PASSWORD MANAGEMENT

Process for setting and managing a 4-digit access password.

19 - INPUT STATUS CHECK AND MANAGEMENT

19.1 - ACCESS TO THE INPUTS STATUS MENU AND MANAGEMENT

How to access and view the status of all control unit inputs.

19.2 - USER 1 24V DG MAXI INPUT MANAGEMENT MENU

Detailed menu for enabling/disabling specific input functions.

20 - RECEIVERS AND REMOTE CONTROLS

20.1 - REMOTE CONTROLS PROGRAMMING

Instructions for programming rolling code and fix code radio transmitters.

20.2 - START COMMAND QUICK SELF-LEARNING

Simplified procedure to store the START command via remote control.

ALARMS

FAULT BLOCKED MOTOR

Indicates a motor blockage or power supply issue requiring immediate attention.

FAULT MOTOR

Signifies a motor short circuit or control unit damage requiring replacement.

FAULT SELF-TEST

Indicates a failure during the photocell self-test sequence.

TROUBLESHOOTING

Operator doesn't respond to any START impulse

Common issue where the gate does not react to start commands.

Gate doesn't move while the motor is running

Problem where the motor runs but the gate remains stationary.

Gate doesn't close automatically

Issue where the automatic closing function fails or is improperly set.