EasyManua.ls Logo

Seagate Nytro 5000 - Page 20

Seagate Nytro 5000
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Seagate Nytro 2.5” x 7mm SSD Product Manual, Rev. A 19
Interface requirements
www.seagate.com
96 16 Controller Busy Time (in minutes)
Contains the amount of time the controller is
busy with I/O commands. The controller is
busy when there is a command outstanding to
an I/O Queue (specifically, a command was
issued by way of an I/O Submission Queue Tail
doorbell write and the
corresponding completion queue entry has
not been posted yet to the associated I/O Com-
pletion Queue). This value is reported in min-
utes.
112 16 Power Cycles Contains the number of power cycles.
128 16 Power On Hours
Contains the number of power-on hours. This
does not include time that the controller was
powered and in a low power state
condition.
144 16 Unsafe Shutdowns
Contains the number of unsafe shutdowns.
This count is incremented when a shutdown
notification (CC.SHN) is not received prior to
loss of power.
160 16 Media Errors
Contains the number of occurrences where the
controller detected an unrecovered data integ-
rity error. Errors such as uncorrectable ECC,
CRC checksum failure, or LBA tag mismatch are
included in this field.
176 16 Number of Error Information Log Entries
Contains the number of Error Information log
entries over the life of the controller.
Table 20 SMART Attributes (Log Identifier 02h) (continued)
Byte # of Bytes Attribute Description