EasyManuals Logo
Home>Seametrics>Measuring Instruments>FT430

Seametrics FT430 User Manual

Seametrics FT430
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
FT430/440/450 INSTRUCTIONS
Seametrics • 253.872.0284 Page 4 seametrics.com
GENERAL INFORMATION
Specications*
* Specications subject to change • Please consult our website for current data (www.seametrics.com).
* For Data Logger operation and set-up, see FlowInspector Instructions.
1 Scaled output pulses have a xed width of 100ms. Maximum pulses per second is 6.5Hz
2 For pulse frequencies <1 Hz, increase setting in SET F menu to 3 or higher.
3 When calculating total resistive load for loop power (volts/.020 amps = ohms) be sure to subtract 400 Ω from the total to account for basic operation
of the FT440
FT440 FT450FT430
Power
7-30Vdc, 4mA
9-30Vdc, 4mA (4-20 mA when
loop-powered)
Lithium “C”, 3.6Vdc, replaceable.
Life is ~5 years depending on
usage.
Display
Rate 5-digit autorange 5-digit autorange 5-digit autorange
Total 8-digit 8-digit 8-digit
Units Rate Units
Gallons/Second/Minute/Hour/Day, Liter/Second/Minute/Hour/Day, Cubic Feet/Second/Minute/Hour/Day, Cubic
Meters/Second/Minute/Hour/Day, Mega Liters/Day, Million Gallons/Day, Fluid Oz/Second/Minute/Hour/Day,
Barrels/Second/Minute/Hour/Day
Total Units
Gallon, Gallon x 1000, Liters, Mega Liter, Cubic Meter, Acre Feet, Cubic Feet,
Cubic Feet x 1000, Million Gallon, Acre Inch, Fluid Ounce, Barrels
Outputs Pulse Output 1 Scaled pulse output, high alarm output or low alarm output. Optoisolated on FT430 and FT440.
1
Pulse Output 2 Pulse pass through
Scaled pulse output, high alarm
output or low alarm output.
1
Pulse pass through
Loop Power
Output
N/A 4-20mA Loop N/A
Sensus Smart
Output
Optional Optional Optional
Set P Range 0.1 - 99999.9 units/pulse 0.1 - 99999.9 units/pulse 0.1 - 99999.9 units/pulse
Input 5V pulse or contact closure 5V pulse or contact closure
Micropower GMR Sensor
(square wave)
Input Range 0.75
2
- 2000Hz 0.75
2
- 2000Hz 0.75
2
- 550Hz
K-Factor Range .001 - 999999.999 .001 - 999999.999 .001 - 999999.999
Flow Alarm Output Range 0.1 - 99999.9 0.1 - 99999.9 0.1 - 99999.9
Operating Temperature -5˚ to 55˚ C (23˚ to 131˚ F) -5˚ to 55˚ C (23˚ to 131˚ F) -5˚ to 55˚ C (23˚ to 131˚ F)
Non-Operating Temperature -40˚ to 75˚ C (-40˚ to 158˚ F) -40˚ to 75˚ C (-40˚ to 158˚ F) -40˚ to 75˚ C (-40˚ to 158˚ F)
Environmental NEMA 4X, IP67 NEMA 4X, IP67 NEMA 4X, IP67
Regulatory
Mark Mark Mark

Other manuals for Seametrics FT430

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Seametrics FT430 and is the answer not in the manual?

Seametrics FT430 Specifications

General IconGeneral
BrandSeametrics
ModelFT430
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals