User Operation Mode
There are 3 different options for user operation mode, card only, card and password,
valid code. The optioned used is common to all users.
Press: 3 0 0 # valid card only
Press: 3 0 1 # valid card and password
Press: 3 0 2 # valid card or password
Setting Door Relay Strike Time
The door relay output can be operated as either normally opened or normally closed,
a maximum current of 10 ampere can pass through the relay if used as normally
opened or 5 ampere if normally closed. The door relay time can be set from 0
seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and
can be changed through the keypad.
Press: 4 new time from 00-99 seconds #
Setting Alarm Signal Output Time
Press: 5 new time from 00-99 minutes #
Setting Door Open Detection
Press: 6 0 0 # to disable this function (factory setting)
Press: 6 0 1 # to enable this function.
In order for this feature to work, door contacts must be connected. There are 2
programming functions that work together in this mode.
a.) If door not closed after opening, keypad buzzer sounds.
b.) If door forced open, keypad buzzer sounds and sends alarm signal.
Setting Security Arrangement
There are two levels of keypad security available for the K2.
Press: 7 0 1 # to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad is locked for 10 minutes.
Press: 7 0 2 # to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad activates and alarm signal.
To disable this feature:
Press: 7 0 0 # factory default setting.