This document describes how to operate the I/O ports of the SiteManager.
This document is supplementary to the “SiteManager Initial Contactleaflets
and the SiteManager product data sheets. These publications can be found
on the Secomea web site.
Version 2.0, April 2013
SiteManager™ xx29/xx39
Working with I/O Ports

Other manuals for Secomea SiteManager 3229

Question and Answer IconNeed help?

Do you have a question about the Secomea SiteManager 3229 and is the answer not in the manual?

Summary

Introduction to SiteManager I;O Ports

About GND, 0 V GND and Shield

Digital Input Ports

Electrical Information for Input Ports

Details input port voltage behavior, ON/OFF states, and the internal 10 Kohm pull-up resistor.

Input Ports Default Functionality

Describes the default assignment of Input Port 1 for GateManager Access and Input Port 2.

Low-side Switching Equipment Example for Inputs

Illustrates connecting a simple switch to Input 1 for controlling remote access via low-side switching.

High-side Switching Equipment Example for Inputs

Demonstrates using a 24V relay with a high-side switching input for controlling equipment connected to SiteManager.

Changing Input 1 Default Functionality

Guides users on reconfiguring the default function of Input Port 1 through the SiteManager GUI settings.

Defining Input Port Email Alerts on GateManager

Explains the process of setting up email alerts triggered by input ports using a GateManager administrator account.

Defining Input Port SMS Alerts on SiteManager xx39

Details configuring local SMS alerts based on input port triggers for SiteManager models with 3G modems.

Digital Output Ports

Electrical Information for Output Ports

Covers the "open drain" nature of output ports, voltage limits, impedance, and current protection.

Output Ports Default Functionality

Explains the default operations of Output Port 1 (GateManager connection) and Output Port 2 (toggle or connection status).

Low-side Switching Equipment Example for Outputs

Shows connecting SiteManager output ports directly to equipment with low-side switching inputs.

High-side Switching Equipment Example for Outputs

Illustrates using relays with SiteManager outputs for high-side switching inputs, requiring external circuitry.

Changing Output 2 Default Functionality

Guides users on configuring Output Port 2 to signal GateManager connection status via the SiteManager GUI.