EasyManua.ls Logo

Secomea SiteManager 1439 - User Manual

Default Icon
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1 of 12
This document describes how to operate the I/O ports of the SiteManager.
This document is supplementary to the “SiteManager Initial Contactleaflets
and the SiteManager product data sheets. These publications can be found
on the Secomea web site.
Version 2.0, April 2013
SiteManager™ xx29/xx39
Working with I/O Ports

Other manuals for Secomea SiteManager 1439

Question and Answer IconNeed help?

Do you have a question about the Secomea SiteManager 1439 and is the answer not in the manual?

Summary

About GND, 0 V GND and Shield

Digital Input Ports

Electrical Information for Digital Inputs

Details electrical characteristics, voltage thresholds, and pull-up resistor behavior for SiteManager input ports.

Default Functionality of Input Ports

Explains that Input Port 1 defaults to controlling GateManager Access; Input Port 2 has no default function.

Low-Side Switching Equipment Example

Illustrates connecting equipment with low-side switching outputs to SiteManager input ports without external components.

High-Side Switching Equipment Example

Demonstrates using a relay to connect equipment with high-side switching outputs to SiteManager input ports.

Changing Input 1 Default Functionality

Guides users on reconfiguring the default action of Input Port 1 via the SiteManager GateManager > I/O menu.

Configuring Input Port Email Alerts

Step-by-step instructions for setting up email alerts triggered by input ports using the GateManager.

Configuring Input Port SMS Alerts

Instructions for setting up SMS alerts for input ports on SiteManager models with integrated 3G modems.

Digital Output Ports

Electrical Information for Digital Outputs

Details the 'open drain' nature, impedance, current limits, and voltage considerations for output ports.

Default Functionality of Output Ports

Explains default actions for Output Port 1 (remote access) and Output Port 2 (GateManager connection status).

Low-Side Switching Equipment Example

Illustrates connecting SiteManager output ports to equipment with low-side switching inputs directly.

High-Side Switching Equipment Example

Shows examples of using relays to connect SiteManager output ports to equipment with high-side switching inputs.

Changing Output 2 Default Functionality

Guides on configuring Output 2 to signal GateManager connection status or be toggled via the GUI.

Notices

Secomea SiteManager 1439 Specifications

General IconGeneral
BrandSecomea
ModelSiteManager 1439
CategoryGateway
LanguageEnglish

Related product manuals