Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17
SECTION 3 INSTALLATION AND CONNECTIONS
NOTE: A Secure Care approved central power supply (A40020901) may be used in place of wall mount
power supplies
A non switched 110VAC (overseas 220AC) duplex outlet (2A) is required within 12 feet (3.7 meters) of each
SMT Advantage 500DE Exit location if a wall mount power supply is used.
The SMT Advantage 500DE Exit Panel can be powered from an optional wall mount local power supply or aa
central power supply may be used to power several SMT ADV 500 DE Exit Panels. The use of emergency power
circuits is highly recommended.
NOTE: Do not extend the power supply cord attached to the wall mount supply. The
maximum distance the duplex outlet should be from the SMT Advantage 500DE Exit Panel is 12
feet (3.7 meters).
Figure 3-1 Power Requirements