SL150 Installation and Setup Guide
5–2
4219
GRN
BLK
(–) GROUND
RED
(+) 12VDC
YEL
4
3
2
1
ZONES
A
B
C
D
F
GH
TAMPER JUMPER
POSITION 229
IN CABINET
(NOT TAMPERED)
4229 REMOTE
(TAMPERED PROTECTED)
TB1
TB2
4-PIN CONSOLE PLUG
(CONNECTIONS SAME AS TB2)
1
2
3
4
DATA OUT
TO CONTROL
DATA IN FROM
CONTROL
TERMINATE EACH PROGRAMMED
ZONE WITH 1000 OHM (1K)
END-OF-LINE RESISTOR
(EACH ZONE'S LOOP RESISTANCE:
700-1300 OHMS)
5
8
11
REED
(TAMPER)
SWITCH
2
E
1
3
4 6
7
9
10
12
DIP SWITCH FOR SETTING
ADDRESS AND ZONE A
RESPONSE TIME
Figure 13. Wiring Connections - 4219 Expansion Module
BRN
GRN
BLK
(–) GROUND
RED
(+) 12VDC
YEL
4
3
2
1
ZONES
A
B
C
D
F
GH
DIP SWITCH FOR SETTING
ADDRESS AND ZONE A
RESPONSE TIME
TAMPER JUMPER
POSITION 229
IN CABINET
(NOT TAMPERED)
4229 REMOTE
(TAMPERED PROTECTED)
TB1
4229
TB2
WHT
GRY
VIO
BLK
YEL
ORG
NO
NC
C
GND
NO
NC
C
RLY
2
RLY
1
RELAYS SHOWN
DEENERGIZED
RELAY
CONNECTOR
RELAY
2
RELAY
1
(TERM 6)
(TERM 4)
(TERM 5)
(TERM 7)
NO C NC
TERMINALS ON
CONTROL PANEL
1
2
3
4
DATA OUT
TO CONTROL
DATA IN FROM
CONTROL
5
8
11
REED
(TAMPER)
SWITCH
2
E
1
3
4 6
7
9
10
12
TERMINATE EACH PROGRAMMED
ZONE WITH 1000 OHM (1K)
END-OF-LINE RESISTOR
(EACH ZONE'S LOOP RESISTANCE:
700-1300 OHMS)
4229 ADDRESS SETTINGS
SWITCH
NUMBER
("—" means "OFF")
0
1
123456789101112131415
2
ON
ON ON ON ON ON ON ON ON
3
ON ON ON ON ON ON ON ON
4
ON ON ON ON ON ON ON ON
5
ON ON ON ON ON ON ON ON
12345
OFF ON
4-PIN
CONSOLE
PLUG
EITHER OR BOTH
CAN BE USED
SWITCH SHOWN
FOR ADDRESS "0"
Figure 14. Wiring Connections - 4229 Expansion/Relay Module