14
PERIODIC INSPECTION
94
• Every 6 months check to see if power cords are damaged, the plug is securely
inserted, dust is accumulated between the socket outlet and the power plug, etc.
Using the product with accumulated dust in the interior may cause re or electric
shock.
•
Never
use a water jet, etc. to clean the inside and outside of the cabinet. If
wetness occurs for any reason, do not use the product until it has completely
dried.
• Once
a year, request the ofce shown on this manual or the dealer from whom
the product was originally purchased to perform the internal cleaning. Using the
product with accumulated dust in the interior may cause re or other accidents.
Note that you are liable for the cost of cleaning the interior parts.
• T
here is the danger of accidents involving electrical shorts circuits or fire
caused by factors such as the deterioration of insulation in electrical and
electronic equipment over time. Check that there are no abnormalities such as
odors from burning.
The items listed below require periodic check and maintenance to retain the performance of this machine and to
ensure safe business operation.
When handling the controller, the player will be in direct contact with it. In order to always allow the player to enjoy
the game, be sure to clean it regularly. Also, it is advisable to provide wet tissue, etc. available for player use.
14 TABLE 01 PERIODIC INSPECTION TABLE
ITEMS DESCRIPTION PERIOD
CABINET Conrm that adjusters
contact oor
Daily
CONTROL PANEL
STEERING WHEEL
Volume inspection Monthly
Gear alignment inspection Every 3 months
Greasing Every 3 months
SHIFT LEVER Switch inspection Monthly
Greasing Every 3 months
START BUTTON Switch inspection Every 3 months
ACCELERATOR & BRAKE Volume inspection Monthly
Gear and spring potion
greasing
Every 3 months
MONITOR Screen cleaning Weekly
Conrm settings Monthly or
when moving
COIN CHUTE DOOR Coin switch inspection Monthly
Coin insertion test Monthly
Selector cleaning Every 3 months
SEAT Greasing to the seat rail Every 3 months
GAME BOARD Conrm settings Monthly
POWER CABLES Inspection, Cleaning 6 months
INTERIOR Cleaning Yearly
CABINET SURFACES Cleaning As appropriate
14 PERIODIC INSPECTION