0000137630 Rev. 2.0 13
!
Paragraph 7!
Programming
Operation
!
!
This makes it possible to set the density of the chemical
product.
Paragraph 8!
Programming
Operation
!
!
This makes it possible to set the input triggers.
When the triggers are present, gives consent to the pump
to run, depending the setting pump function:
No Trg= the triggers are disabled.
Trg 1= the pump run when only the trigger 1 is
enabled.
Trg 2= the pump run when only the trigger 2 is
enabled.
Trg 1&2= the pump run when the both triggers
(1&2) are enabled.
Paragraph 9!
Programming
Operation
!
!
This makes it possible to set unit of measurement, which
can be:
L/h= liter per hour.
ml/m= milliliter per minute.
Gph= Gallon per hour.
%= the percentage of the maximum flow-rate.
Paragraph 10!
Programming
Operation
!
The buzzer is active when there is an alarm condition.
This makes it possible to set the buzzer the system to On
or Off.
Paragraph 11!
Programming
Operation
!
This makes it possible to set the level alarm as follow:
Stop= the pump stops.
Run= the pump keeps running.
Density!
1.00 kg/L!
Triggers!
No Trg!
Units!
L/h!
Buzzer!
Off!
Level Alarm!
Stop!