8. PROGRAMMING
The programming menu can be accessed by simultaneously pressing the Cal and Set
keys for at least 3 seconds.
Upon release of the keys the display will show:
To prime the pH pump, press the UP button for at least 3 seconds and release it to stop
the operation. To prime the H
2
O
2
pump repeat the same procedure pressing the DOWN
button for at least 3 seconds.
Use Enter to access the sub-menus:
Setpoint
Dos type
OFA time
Alr Band
Type
pH Measure
Setpoint 7.4 pH
Press Enter and the + and - keys to change
the Set Point value (0÷14 pH)
Press Enter and the + and - keys to change
the Set Point type.
Acid
Alkaline
Press Enter and the + and - keys to set the
OFA time to OFF or from 1 to 240 min. (see
Paragraph 9.5)
pH Measure
Alr Band 3.0pH
Press Enter and the + and - keys to set the
band alarm from 1 to 3 pH.
Press Enter and the + and - keys to change
the dosing type.
PROP (see Paragraph 9.1).
ON/OFF (see Paragraph 9.2).
OFF (dosing disabled)
Press Enter and the + and – keys to change
the language:
FR, EN, IT, ES, DE