0000137188 Rev. 1.0
3
1. GENERAL INTRODUCTION
The Pool Basic Pro EVO control method belongs to a new line of instruments carefully
developed by the supplier for the innovative management of pools. This device is easy
to use and permits continuous control of the pH.
The peristaltic pumps have a 1,5 l/h flow rate for pH regulation and have a pressurised
injection flow rate up to 1.5 bar.
This easy-to-use instrument does not require special maintenance operations. It is
equipped with a self-regulation procedure and automatic control of the electrode’s state.
2. INSTALLATION PRECAUTIONS
WARNING!!!
Disconnect power before carrying out ANY operation inside the
control panel of the Pool Basic Pro EVO device.
NON-OBSERVANCE OF THE INSTRUCTIONS CONTAINED IN THE PRESENT
MANUAL COULD CAUSE INJURY TO PEOPLE AND/OR DAMAGE TO THE DEVICE.
WARNING
During installation of the Pool Basic Pro EVO device, proceed as follows:
Make sure that the supply voltage coincides with the one indicated on the label on
the side of the device.
Make sure that the injection pressure is below 1.5 bar.
Make sure that the pump’s protective cover is properly latched.
Make sure that the suction hose is immersed with the relative foot (PVC hose) in the
tank of the product which must be injected and that it is connected to the pump
(symbol on cover ). After carrying out the checks stated above, tighten the
connector nut.
Connect one end of the delivery hose (symbol on cover) to the pump and connect
the other end to the pool through the injection valve.
NOTE: To insert the product which must be injected into the pump when starting for the
first time and every time the tank is changed, set the switch to forced running
using the button.