1.5 Programming a Directory Record with a PIN into a TEC1A
The following steps show how to set a directory record (Code, Name, Phone # and PIN
for entrance 1 with 24/7 access) using the keypad. It assumes the TEC1A is powered on
and that the Welcome Page e.g. “Press # to View Directory” is displayed before starting.
Note that Steps 4 and 5 are included to check if PINs are enabled. Once PINs are enabled,
steps 4 and 5 can be skipped for future entries. For all other settings please refer to
“TEC1A Series Menus”.
Steps to Program a Directory Record with a PIN into a TEC1A using the Keypad
#
Step Description
Keypad Action
Resulting Display
1
Enter Programming
Mode
Press * and 0 at same time
PASSWORD
2
Enter Password
Press 6 digit password (default is
“777777”) then *
MAIN MENU 1 - 8
3
Select Codes & Names
Press 1
CODES & NAMES
SELECT 1 - 9
4
Skip this step if you know
PINs are enabled
Press 8
ENABLE PINS = 0 or
ENABLE PINS = 1
5
Complete check of
Enable PINs setting
If ENABLE PINS = 0, press 1 then *
If ENABLE PINS = 1, press *
CODES & NAMES
SELECT 1 - 9
6
Select Add New
Press 1
CODE =
7
Enter a code e.g. 100
Press “100” then *
NAME =
8
Enter a name e.g. JOHN.
Note: # moves cursor to next
character
Press J# O# H# N# then *
PHONE # =
9
Enter phone number
e.g. 3055551212 then *
PIN =
10
Enter 4-digit PIN
e.g. 1234 then *
ENTRANCE = 0
11
Set Entrance 1
Press 1 then *
TG GROUP = 0
12
Set Group 0 (24/7 access)
Press 0 then *
CODE =
13
Enter more records
OR
Repeat as needed from end of step 6
with new data.
Note that no two codes and no two
pins can be identical.
14
Exit Programming Mode
Press *0 together
Welcome Page