EasyManua.ls Logo

Selmo Dynamic - Functional Characteristics

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Selmo
Comfort technology
division
“Dynamic”
Electronic control for towel heaters
-
March 2018
Selmo
Electronic
Via Pacinotti, 24 - 35030 Rubano (PD) Italy- Tel 049.8976761, Fax 049.8976085 - www.selmo.it
EN
Functional characteristics
Function mode: Comfort, Night, Antifreeze, Fil-pilote, Chrono, Timer 2h, Stand -by.
-
In ‘’Comfort’’ mode:
the electronic control maintains the set temperature at the value set by the user.
-
In ‘’Night’’ mode:
the electronic control maintains the ambient temperature at an inferior value respect at
‘’Comfort’’ temperature.
-
In ‘’Antifreeze’’ mode:
the electronic control maintains the temperature over 7°C.
-
In ‘’Fil-Pilote’’ mode:
the electronic control operation is decided by the signal sent by the ‘’Fil-Pilote’’ system.
-
In ‘’Timer 2h’’ mode:
the electronic control activates the heating element for 2 hours, unconditionally by
set temperature. At the end of this period, the thermostat operates again with the
previously set mode. During the 2 hours, for security reasons, the ambient temperature
can’t go higher than 32°C.
-
In ‘’Chrono’’ mode :
the electronic control operates according to a daily program with weekly repetition,
the program can be setted by the user.
-
In ‘’Stand-by’’ mode:
the heating element is deactivated but the electronic control is operative.
Other information:
-
Big backlight display shows: hour, setted temperature and function/mode.
-
3 presetted daily programs and 1 program settable by the user.
-
‘’Open window detection ’’ Function: this function deactivates the heating element
for a max of 30 mins if there is an open window in the room, allowing an energetic saving.