Basic parameters P1
Basic parameters P1 are used for the thermostat user settings. To change the
selected parameter, hold key for approximately 5 seconds. Parameter
starts to flash. Press key or to set the parameter value. To store the
setted value, again hold key for approximately 5 seconds. Group P1
contains the following parameters; (factory setting):
- [P1.1] night temperature (6 °C ÷ 26 °C); (17 °C)
- [P1.2] temperature reduction in ECO mode
(0 °C ÷ -9 °C); (-3 °C)
- [P1.3] frost protection temperature (0 °C ÷ 20 °C); (6 °C)
- [P1.4] temperature sensor calibration (-2 °C ÷ 2 °C); (0 °C)
- [P1.5] auxiliary temperature sensor calibration
(-2 °C ÷ 2 °C); (0 °C)
- [P1.6] display of measured temperatures (1 - room, 2 - outdoor,
3 - room and outdoor alternating, 4 - requested temp.); (1)
- [P1.7] beeper mode (- - - silent, 1 - by typing, 2 - by timer
switchover, 3 - by typing and timer switchover); (1)
- [P1.8] display of controlled devices (1 - visible, 2 - hidden); (1)
- [P1.9] temperature increase in PARTY mode
(0 °C ÷ -9 °C); (0 °C)
- [P1.10] temperature display by ESC command in normal display (see table):