DUAL
CHANNEL-VERTICAL
INPUT
DUAL
CHANNEL—VERTICAL
INPUT
DUAL
VECTOR
CHOPPED
A&B
INPUTS
DUAL
ALTERNATE
This
push
button
switch
gives
instant
selection
of
five
different
“displays”
or
modes
of
operation.
The
CHANNEL
A
and
CHANNEL
B
modes
provide
single
trace
display
of
the
selected
channel.
DUAL ALTERNATE
This
switch
provides
dual
trace
display
of
the
CHAN-
NEL
A
and
CHANNEL
B
signals.
The
signal
from
one
input
channel,
CHANNEL
A
for
example,
is
dis-
played
on
the
first
sweep
cycle.
On
the
next
sweep
cycle
the
other
channel
is
displayed.
This
is
the
re-
commended
mode
to
use
for
most
dual
trace
op-
erations.
DUAL
CHOPPED
This dual
trace
mode
is
most
useful
at
slow
sweep
speeds
and
when
it
is
desired
to
have
dual
trace
dis-
play
when
using
the
60
cycle
or
EXT.
sweep
pro-
visions.
The
DUAL
CHOPPED
mode
uses
a
100KHz
square
wave
to
switch
the
input
between
CHANNEL
A
and
CHANNEL
B.
This
will
provide
a
continuous
steady
display
of
both
channels
at
slow
sweep
speeds.
The
DUAL
CHOPPED
mode
is
intended
to
be
used
only
with
the
MANUAL
TRIGGERED
and
FREE
RUNNING
sweep
modes.
The
AUTO
TRIGGERED
function,
because
of
its
extreme
sensitivity,
will
tend
to
trigger
on
the
100KHz
chopping
signal.
VECTOR
A&B
INPUTS
This
display
mode
converts
the
PS163
to
a
full
sensi-
tivity
Vector
scope
or
X-Y
scope.
The
input
to
CHANNEL
A
will
be
displayed
vertically;
the
input
to
CHANNEL
B
will
be
displayed
horizontally.
CHANNEL
A
and
B
INPUT
CONTROLS
The
CHANNEL
A
and
CHANNEL
B
amplifiers
are
electrically
identical
and
a
description
of
one
will
apply
to
the
other.
PPV
PER
DIV.
This
switch
adjusts
the
input
sensitivity
of
the
amp-
lifiers,
and
is
calibrated
in
volts
per
division.
The
center
knob
of
this
switch
is
a
vernier
control
that
adjusts
the
sensitivity
of
the
amplifier
between
switch
positions.
For
normal
operation
with
calibrated
in-
put
this
control
should
be
turned
fully
clockwise
until
it
snaps
into
the
detent
provided.
The
input
amplifiers
are
calibrated
to
read
input
volt-
age
directly
when
using
the
Sencore
39G34
LO
CAP
PROBE.
No
multiplication
of
readings
is
required
when
using
the
LO
CAP
PROBE.
The
maximum
in-
put
voltage
with
the
LO
CAP
PROBE
is
5000
volts
peak
to
peak
AC
or
1000
volts
DC.
When
a
direct
probe
is
used,
all
readings
of
the
input
voltage
are
multiplied
by
.1.
The
maximum
input
voltage
direct
is
600
volts
DC
plus
peak
AC.
‘CHANNEL
A
O
PPY
per
ow.
500
05
|
©
TURN
FULL
CLOCKWISE
oc
TO
READ
PPY
BALANCE
READ
SCALE
DIRECT
WHEN
USING
LO
CAP
PROBE
COUPLED
COUPLED
©)
INPUT
A
R-Y
VECTOR
INPUT
TRACE
POSITION
CAL.
VOLTS
PP
9