- 20 _EN- SL320005700 Ed.00 - 04-2011
9. TROUBLESHOOTING
Problem Cause Remedy
The machine does not turn on. The main switch is off (positioned on “O”). (Chap.6) Press the switch into position “I”.
The machine is not plugged in. Insert the plug in a suitable outlet.
The tap leaks. The tap plug is not lubricated. (Fig.38) Lubricate the plug.
The plug is defective. Replace the plug.
Product leaks from the rear part of the bowl. The bowl is not fi tted correctly in place . (Chap.7.5) Check the positioning of the bowl.
The bowl seal is not lubricated. (Fig.34) Lubricate accordingly.
The seal is defective. Replace the seal.
The auger does not turn The switch is positioned on “O”. (Chap.6) Press the switch into position “I”.
Blocks of ice inside the bowl. Switch off the machine, allow the bowl contents to melt
and check that the product has been correctly diluted.
The machine does not make granita. The switch is positioned on “O”. (Chap.6) Press the switch into position “I”.
The machine is near sources of heat. Install the machine in a suitable place.
There is insuffi cient ventilation.
The condenser is dirty. (Chap.7.9) Call in a specialized technician to clean the
condenser.
The consistency has not been adjusted correctly.
(Chap.6.4)
Correctly adjust the consistency.
Timer levers in position “
”. Place the levers in position “ ” see sect. 6.7
The auger is noisy. The front seal has been applied incorrectly. (Fig.32) Check that the seal is applied correctly.
The seal is not lubricated. (Fig.33) Lubricate the seal accordingly.
The tap does not dispense Blocks of ice inside the bowl. Switch off the machine, allow the bowl contents to melt
and check that the product has been correctly diluted.
If the machine malfunctions due to causes other than those listed in this table or the proposed remedies do not solve the problem, contact a specialized
technician.