Send the downlink command (HEX) via FPort=2:
00 89 00 11 22 0A 00 38 B4
0x00
0x89
0x00
prepareId_L
prepareId_H
duty_L
duty_H
crc-L
crc-H
00
89
00
11
22
0A
00
38
B4
ACK Response:
00 1F 00 11 22 01 00 78 0F
0x00
0x1F
0x00
prepareId_L
prepareId_H
result
0x00
crc-L
crc-H
00
1F
00
11
22
01
00
78
0F
Command List:
Description
Command
Set Uplink interval = 1 minute
008900112201009050
Set Uplink interval = 5 minutes
00890011220500F037
Set Uplink interval = 10 minutes
00890011220A0038B4
Set Uplink interval = 15 minutes
00890011220F0080CA
Set Uplink interval = 20 minutes
0089001122150061A2
Set Uplink interval = 30 minutes
00890011221E00C946
Set Uplink interval = 60 minutes
00890011223C004A56
10.2 Reboot the device
FPort = 2
Command: 00C800000000002B26
10.3 How to send downlink
Example: use the Helium Console to send