5. SPECIFICATIONS
Display
5 red LED digits 14,2mm (-19999 à 99999)
AC Versions
85 to 250VAC
50/60Hz
15VA
Isolation : 2300 Vrms for 1 min. to all inputs and outputs
Operating temperature : 0 to 50°C (45°C if 3 plug-in cards are
installed)
24VAC
50/60Hz
15VA
Isolation : 500 Vrms for 1 min. to all inputs and outputs
Operating temperature : 0 to 50°C (45°C if 3 plug-in cards are
installed)
DC Version
11 to 36VDC
11W
Operating temperature below 40°C if the power supply is below
15VDC and 3 plug-in cards are installed
Analog/digital
converter
16bits resolution
Bridge excitation
Jumper selectable
5VDC, 65mA max, +/-2%
10VDC, 125mA max, +/-2%
Temperature coefficient (ratio metric): 20ppm/°C max
Custom
linearization
Data point pairs
Selectable from 2 to 16
Display range
from -19999 to 99999
Decimal point
0 to 0.0000
Memory
Nonvolatile EEPROM retains all programmable parameters and display values.
Certifications and
compliances
Electromagnetic immunity:
Conform to EN 50082-2
Electrostatic discharge
EN 61000 - 4 - 2
Level 3: 8 kV air
Electromagnetic RF fields
EN 61000 - 4 - 3
Level 3: 10 V/m 80 MHz to 1GHz
Fast transients (burst)
EN 61000 - 4 - 4
Level 3: 2 kV power
Level 4: 2 kV (I/O)
RF conducted interference
EN 61000 - 4 - 6
Level 3: 10 Vrms de 150 kHz - 80 Mhz
Electromagnetic emission:
Conform to EN 50081 -2
RF interference
EN 55011
Enclosure class A
Power mains class A
Notes: Self-recoverable loss of performance during electromagnetic interference (EMI) at 10 V/m:
measurement error exceeds unit specifications. For operation without loss of performance:
- mount unit in a sheet-metal enclosure (Buckeye SM7013-0 or equivalent)
- route power and I/O cables in metal conduit connected to earth ground.
For more information, refer to guide treatment against the effects of EMC.
Note : In load limitation operation, always lock the device configuration with an access code (the access code