EasyManua.ls Logo

Senztek SolaStat-Plus - Specifications

Senztek SolaStat-Plus
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SolaStat™-1-3 Installation Guide
Version 1.1 – April 2013 Page 31
SP ECIFICATIONS
Power Supply.
Supply Voltage 85 264 Vac (high) OR 22 85 Vdc (medium)
(must be specified at time of ordering)
Max power usage 5VA + external loads.
Relay Outputs. Pump: 10A (240Vac) Resistive for pre-wired option
16 A max (240 Vac) Resistive for permanent wired option
1HP (240Vac) Inductive (motor)
HWC: 10A (240Vac) Resistive for pre-wired option
16 A max (240 Vac) Resistive for permanent wired option
Note that 3.6kW element under certain condition will draw over
16A. Hence we recommend using max 3kW element or external
relay.
Sensors.
Display range -20 ~ +15C [-4 ~ + 318 °F]
Control Range -40 ~ +150°C [-40 ~ 302 °F]
PVC Sensor -40 ~ +105°C [-40 ~ 221 °F]; 4mm [0.16 inch] diameter, UV
resistant. (Standard Models)
Teflon Sensor -40 ~ +250°C [-40 ~ 482 °F] peak; 4mm [0.16 inch] diameter, UV
resistant. (Special Order)
Accuracy +/-1°C @ 25°C; +/- 1.8°F@ 77°F
EMC and Safety Compliances.
Emissions EN 55022-A, CTick.
Immunity EN 50082-1.
Safety Compliance EN 60950, CTick.
General Specifications. (Unless otherwise stated in other input specifications.)
Operating Temperature 0~50°C
[32 ~ 122 °F]
Operating Humidity 90% RH Max. Non-Condensing
Enclosure Construction Polycarbonate - Impact Resistant
UL94 V-2 Non Burning, UV Stabilized
Water resistant to IP54. Rear entry option available.
Dimensions L=167mm [6 ½ inches],
(excluding glands and cables) W=142 [5 ½ inches],
H=40mm [1 ½ inches],
Weight = 1000grams [35 oz]
(Standard model + sensors + packaging, without power plug, pump socket and HWC socket)
Product Liability. This information describes our products. It does not constitute guaranteed
properties and is not intended to affirm the suitability of a product for a particular application.
Due to ongoing research and development, designs, specifications, and documentation are
subject to change without notification.
Regrettably, omissions and exceptions cannot be completely ruled out. No liability will be
accepted for errors, omissions or amendments to this specification. Technical data are always
specified by their average values and are based on Standard Calibration Units at 25°C, unless
otherwise specified. Each product is subject to the ‘Conditions of Sale’.