Do you have a question about the SEW-Eurodrive MOVIDRIVE MDP90A-0100-503-4-C00 and is the answer not in the manual?
Input Voltage | 380-500 V AC |
---|---|
Control Method | Vector Control |
Protection Class | IP20 |
Frequency Range | 0-400 Hz |
Control Unit Type | MDP90A |
Communication Interface | PROFIBUS DP |
Operating instructions for the MOVIDRIVE modular application inverter.
Outlines user responsibilities for ensuring safety notes are observed and complied with.
Specifies the intended use of the product and applicable directives and standards.
Provides guidance on proper installation and assembly procedures.
Details prohibited applications and conditions for use at altitudes above 1000m.
Ensures the product is correctly attached to the ground connection.
Details requirements for protective separation of power and electronics connections.
Covers safety notes related to starting up and operating the device.
Describes the different connection variants for the MOVIDRIVE modular application inverter.
Details the unit structure of the MDP power supply module, including views and connections.
Explains the unit structure of MDA and MDD axis modules, including views and connections.
Specifies the correct tightening torques for various screw connections to prevent damage.
Provides guidelines for the mechanical installation of modules.
Defines minimum clearance requirements for unobstructed cooling and proper mounting.
Outlines the steps for installing modules within a control cabinet.
Explains how to arrange axis modules based on nominal output current.
Covers essential safety precautions and procedures for electrical installation.
Provides information and notices regarding line connection procedures.
Details motor connection procedures, including protection caps and cable types.
Specifies requirements for the external 24 V supply voltage connection.
Covers safety precautions and installation guidelines for braking resistors.
Details permitted mounting positions and minimum clearances for braking resistors.
Explains protection methods against thermal overload for braking resistors.
Provides recommendations for optimizing system EMC and eliminating interference.
Provides terminal assignments for various modules and connections.
Illustrates wiring diagrams for various connections.
Covers general safety and initial connection procedures for startup.
Provides critical notices regarding power connection timing and sequence.
Emphasizes that cables must only be connected/disconnected in a de-energized state.
Lists the necessary hardware and software conditions for successful startup.
Illustrates the functional division and steps for an exemplary startup procedure.
Provides a checklist of essential steps for complete startup.
Details how fault codes are displayed and their attributes.
Provides a reference for faults detected by the power supply module.
Lists and describes faults specific to the axis modules.
Explains how errors are acknowledged and the resulting system responses.
Provides a reference for default and parameterizable fault responses.
Details the technical specifications for MDP power supply modules.
Lists performance data including nominal power, current, voltage, and dimensions.
Details technical specifications for MDA and MDD axis modules.
Lists performance data for MDA single-axis modules across various types and sizes.
Lists performance data for MDD double-axis modules across various types and sizes.
Presents dimension drawings for power supply, axis, and master modules.
Lists technical data for various option cards.
Lists technical data for encoder interfaces on basic devices and CES11A card.
Provides technical data for braking resistors, filters, and chokes.
Lists technical data and dimensions for BW braking resistors.
Details technical data and specifications for TCB thermal circuit breakers.
Covers underlying standards and integrated safety technology concepts.
Describes the developed and tested safety technology of the application inverter.
Defines the safe state for safety-related operation as Safe Torque Off (STO).
Explains the drive safety function Safe Torque Off (STO) and its implementation.
Details available drive-related safety functions like STO and SS1(c).
Lists restrictions for using drive safety functions and potential dangers.
Outlines mandatory requirements for safety-related applications.
Specifies MOVIDRIVE modular variants permitted for safety-related applications.
Details installation requirements for safety-related applications, including wiring and cabinet setup.
Outlines requirements for external safety controllers and relays used with the STO input.
Mandates documentation and checks for implemented drive safety functions post-startup.
Specifies limits and diagnostic function usage for safe operation.
Describes connection variants for safety-relevant applications.
Lists characteristic safety values according to EN 61800-5-2 and EN ISO 13849-1.