04/2000
Gear Units
R..7, F..7, K..7, S..7 Series, Spiroplan
®
W
Edition
05/2001
Operating Instructions
10503013 / EN

Questions and Answers

  • A
    Angel WongAug 9, 2025
    Why is oil leaking from the breather valve on my SEW-Eurodrive Industrial Equipment?
    • M
      Megan JonesAug 9, 2025
      If oil is leaking from the breather valve of your SEW-Eurodrive Industrial Equipment, it could be due to having too much oil. In this case, correct the oil level. Alternatively, the drive might be installed in an incorrect mounting position. To resolve this, fit the breather valve correctly and adjust the oil level.
  • E
    Eric WardAug 16, 2025
    How to troubleshoot unusual regular running noise in SEW-Eurodrive RF 77 Industrial Equipment?
    • S
      susanwebbAug 16, 2025
      An unusual, regular running noise in your SEW-Eurodrive Industrial Equipment could be due to a meshing/grinding noise, indicating bearing damage. Check the oil and replace the bearing. Alternatively, a knocking noise might suggest an irregularity in the gearing.
  • G
    George PonceAug 25, 2025
    What causes unusual irregular running noise in SEW-Eurodrive Industrial Equipment?
    • D
      Dillon WallAug 26, 2025
      An unusual, irregular running noise in your SEW-Eurodrive Industrial Equipment may be caused by foreign bodies in the oil. Check the oil.
  • P
    Patricia StevensonAug 31, 2025
    Why is the output shaft not rotating on my SEW-Eurodrive RF 77?
    • J
      Jared HicksAug 31, 2025
      The output shaft of your SEW-Eurodrive Industrial Equipment not rotating, even when the motor is running or the input shaft is rotating, indicates that the shaft hub connection is interrupted in the gear unit.

Summary

Important Notes and Warnings

Safety Notes and Precautions

General Safety, Designated Use, and Transport

Covers general safety, preliminary remarks, designated use, and transport guidelines.

Installation, Startup, and Maintenance Safety

Safety precautions for setup, operation, and maintenance procedures.

Mechanical Installation Procedures

Gear Unit Startup and Running-In

Startup Procedures for Helical-Worm & Spiroplan W Units

Specific startup notes and running-in periods for these gear unit types.

Startup for Helical, Parallel Shaft, and Helical-Bevel Units

Startup guidelines for helical, parallel shaft helical, and helical-bevel units.

Troubleshooting Gear Unit Problems

Identifying and Resolving Gear Unit Issues

Lists common gear unit problems, their possible causes, and remedies.

Inspection and Maintenance Guidelines

Maintenance Schedules and Lubricant Checks

Details inspection periods and lubricant replacement schedules.

Lubricant Selection and Quantities

SEW-Eurodrive RF 77 Specifications

General IconGeneral
SeriesRF
Size77
Nominal Power Range0.12 to 22 kW
Input OptionsIEC standard motor, brake motor, servo motor
Output OptionsSolid shaft, Hollow shaft
Protection ClassIP65
LubricationSynthetic oil
CoolingNatural convection, fan cooling optional