EasyManua.ls Logo

Sewha SI 4010 - Page 28

Sewha SI 4010
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIGITAL WEIGHING INDICATOR
SI 4010
28
1
+9V
LSB
0
1
2
3
4
5
MSB
6
0
-9V
6-1-4 Data Format(1) : ID Number will not be transferred. (Refer “F-function 37”)
,
,
+/-
Including Decimal
point
k
g
CR
LF
Header 1.
Header 2.
Data Byte ( 7 or 8 byte )
(F37 setting)
Unit
Header 1. : OL : Over Load, Under Load
ST : Display weight “Steady”
US : Display “Un-Steady”
Header 2. : NT : Net-Weight
GS : Net-Weight, under TARE
Data Bit(Number) 2B(H) : “+” Plus
2D(H) : “-“ Minus
2D(H) : “ “ Space
2E(H) : “.” Decimal Point
Unit : kg, g, t
6-1-5 Data Format(2) : ID Number + Data Transference (Refer “F-function 18, 37)
,
,
,
+/-
Including Decimal point
CR
LF
ID Number
Header 1
Header 2
Data Byte
( 7 or 8 byte )
(F37 setting)
Unit
Header 1. : OL : Over Load, Under Load
ST : Display “Steady”
US : Display “Un-Steady”
Header 2. : NT : Net-Weight
Start Bit
Data Bit
Parity Bit