Sewage Lifting unit with cutting
system Operation manual
Abwasserhebeanlagen mit Schneid-
werk Betriebsanleitung
Station de relevage des eaux usées
à pompe dilacératrice
• Mode d'emploi
Stazione di pompaggio acque reflue
con trituratore Istruzioni per l'uso
Afvalwater opvoerinstallaties met
versnijder • Gebruikshandleiding
Equipos elevadores de aguas resi-
duales con bomba trituradora
• Manual de instrucciones
Unidades elevatórias de águas
residuais com unidade de corte
• Manual de instruções
SANICUBIC
®
GR
SANICUBIC
®
1GR SANICUBIC
®
2GR
IT
NL
ES
PT
UK
DE
FR
9010
06.19

Table of Contents

Questions and Answers

  • M
    Maria SchroederAug 5, 2025
    Why is my SFA SANICUBIC GR motor not running?
    • J
      Jeremy FriedmanAug 5, 2025
      Several factors can cause the motor of your SFA Water Pump not to run. It could be due to voltage issues (too low or a complete lack of voltage), in which case you should check the main supply. Other potential causes include a wrong power connection (requires correction), a defective electric cable (requires replacement), a fault at the condenser (requires replacement), a blocked rotor (needs cleaning), a switched-off motor protection system due to overheating, blocking, or voltage error (needs checking), a control system error or defective pressure switch (needs checking), leaking pneumatic hose or connection (needs checking or replacement), or a defective motor (requires replacement).
  • S
    Shannon RiveraAug 12, 2025
    What to do if my SFA SANICUBIC GR motor is running but not conveying?
    • C
      Cheryl MartinAug 12, 2025
      If the motor of your SFA Water Pump is running but not conveying, the issue might stem from several causes: * The rotor could be stopped up or worn, requiring cleaning or replacement. * The back-kick flap, gate valve, pressure main, or suction joints might be fowled up, needing cleaning (and opening the gate valve if it's closed). * The rotational direction could be wrong, needing correction. * The chamber ventilation or pump housing ventilation might be stopped up, also requiring cleaning.
  • M
    mhartAug 20, 2025
    Why does my SFA Water Pump motor run then switch off?
    • E
      Eugene WhitneyAug 20, 2025
      If your SFA Water Pump motor runs and then switches off, it could be due to a voltage error or fluctuations, which needs correction. Another possible reason is that the thermo-protection is wrongly set, which needs checking.
  • D
    dianepatelAug 27, 2025
    What to do if SFA Water Pump motor does not switch off?
    • B
      brewerandrewAug 27, 2025
      If the motor of your SFA Water Pump does not switch off, it could be due to a control system fault or the pressure switch function not being in order.

Summary

Safety

Marking of instructions in the operating manual

Explains symbols for warnings and dangers.

Personnel qualifications and training

Details required qualifications for operation and maintenance personnel.

Dangers from non-observance of safety instructions

Lists hazards from not following safety guidelines and legal consequences.

Safety-awareness at work

Emphasizes following safety instructions, national regulations, and internal rules.

Safety instructions for customer;operator

Provides specific safety advice for users regarding hazards and protective devices.

Safety instructions for maintenance, inspection and assembly

Outlines safety measures for service personnel, including shutdown procedures.

Unauthorised re-equipping and spare-part production

Discusses limitations on modifications and the use of original spare parts.

Prohibited methods of operation

Lists forbidden operational practices and the importance of limit values.

General

Introduction

Introduces the operating manual and the SANICUBIC ® GR product series.

Queries and orders

Instructs users on how to make inquiries or place orders.

Technical specifications

Provides detailed technical data including power, voltage, speed, and materials.

Area of usage

Describes the intended applications for the effluent lifting units.

Scope of delivery

Lists the components and accessories included with the product.

Transport and Interim Storage

Transport

Guidelines for safely moving the equipment, emphasizing not to drop it.

Interim storage;conservation

Advice on storing the machine in a cool, dry, and frost-free environment.

Description

General

Provides a general overview of the SANICUBIC ® GR lifting units.

Construction and work method

Explains the unit's build and operational principle, including how it pumps liquid.

Installation

Preparations

Details site requirements like ventilation, dimensions, and structural support.

Assembly

Instructions for installing the unit, covering pipeline and electrical connections.

Initial Operation

Maintenance; Repairs

Inspection and maintenance intervals

Specifies how often to perform checks and maintenance based on usage type.

Maintenance work

Details procedures for cleaning collection chambers and back-kick flaps.

Malfunctions, Causes and Troubleshooting

Warranty

Technical Modifications

Appendix A: Main dimensions

Appendix B: Power diagram

Appendix C: Spare parts list

Appendix D: Section diagram and spare parts list of the pump

Section diagram

Visual representation of the pump's internal structure with numbered components.

SFA SANICUBIC GR Series Specifications

General IconGeneral
BrandSFA
Voltage220-240 V
Max Head / Maximum vertical discharge11 m
Maximum horizontal discharge110 m
Liquid Temperature35 °C
Number of available inlets4
Ingress ProtectionIP68
ModelSANICUBIC GR
TypeGrinder Pump
Flow Rate11 m³/h
Outlet Diameter / Discharge pipe diameter50 mm