EN
22
SC_2VX
6.3.2.4 Consulting software versions and configuration
Allows you to consult:
- the tank-pump combination (Model) selected for the installation,
- the software versions for the control box’s motherboard and the
screen card. This may be necessary in case of maintenance or interven-
tion on the enclosure.
SC_2VX
Logs
SC_2VX
HW:
SW:
2.2
3.3.0
2.2
3.7.1
Logs>Version
Model: SANICUBIC 2 VX BLDC
Motherboard Screenboard
10.1Returntothestart-up
screen
to change the model.
• Press to return to the main menu.
This information cannot be changed.
6.3.3 Settings Menu
SC_2VX
你好
Hello
Bonjour
Ciao
HALLO
HO
LA
Allows you to:
- set the date and time,
- adjust the brightness of the
display, activate/deactivate the
audible alarm,
- set the pump delay time,
- set the delay time for the aux-
iliary pump to start,
- select the frequency of mainte-
nance,
- set the BMS parameters
6.3.3.1 Setting the date
The date setting is particularly important for alarm management and
maintenance monitoring.
SC_2VX
Settings
Date
SC_2VX
Settings>Date
• Then press and to select the value.
• Then press and to switch from day to month and month to
year.
• Press to conrm the choice.
• Press to return to the main menu.
6.3.3.2 Setting the hour
The hour setting is imporant for alarm management.
SC_2VX
Settings
Hour
SC_2VX
Settings>Hour
• Then press and to select the value.
• Then press and to switch from hour to minute and minute to
second.
• Press to conrm the choice.
• Press to return to the main menu.
6.3.3.3 Various
SC_2VX
Settings
Various
Then press and to scroll
through the submenus. Conrm
with to enter the submenu.
Brightness adjustment
Allows you to adjust the brightness of the display during use.
SC_2VX
Settings>Various
SC_2VX
Settings>Various
• Press and to select the value.
• Press to conrm the choice.
• Press to return to the main menu.
Enable/disable audible alarm
Selects whether the alarm notication (display of an alarm window) is
accompanied by an audible signal.
SC_2VX
Settings>Various
SC_2VX
Settings>Various
• Press and to choose between «Enable» or «Disable».
• Press to conrm the choice.
• Press to return to the main menu.
6.3.3.4 Setting the Stop delay time
The stop delay time is an additional pumping time when the pump’s
stop level has been reached. It allows the tank to be emptied as much
as possible and optimises the pumping of surface matter.
SC_2VX
Settings
Stop delay
SC_2VX
Settings>Stop delay
Mode: Manual
Duration: 2s
details see
10.3Learningloops
• Press and to choose between «Manual» and «Automatic».
• Press and to switch from Mode to Duration.
• Press and to choose the duration.
• Press to conrm the choice.
• Press to return to the main menu.
Note:
- If the automatic management mode has been chosen, the “Duration”
parameter cannot be modied.
- If Sanipump SLD was selected, the value is 0 s and cannot be changed.
6.3.3.5 Setting the start of the auxiliary pump
When one of the pumps is running continuously, the second pump is
activated after the time set in this menu to support the rst pump. This
activation of the auxiliary pump corresponds to an abnormal case (e.g.
a hydraulic problem on the 1st pump) and will cause the automatic de-
activation of the 1st pump.
To be relevant, the set time must be at least twice the duration of a
normal ON-OFF cycle.