EasyManua.ls Logo

Sharp 4T-C60AH1X - 4. Writing the Panel size.; Panel Size Setting Procedure; 5. POWER CONSUMPTION; Power Consumption Measurement Method

Sharp 4T-C60AH1X
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4T-C6070AH1X
5 – 5
4. Writing the Panel size.
1) Enter the adjustment process mode [ PAGE 2/13 (INIT) ]
2) Point the cursor to [PANEL SETTING]
3) Select Panel Size and press [enter] key
02/11 [INIT]
FACTORY INIT
GENERAL :
PANEL SETTING
PUBLIC MODE OFF
OPERATION ACUTIME 0008H 56M
RESET OFF
5. POWER CONSUMPTION
Power Consumption Measurement Method
Aging time : minimum 30 minutes
Signal : Color Bar
Audio frequency : 400 Hz
AV Mode : Dynamic
Picture Setting : Backlight/ Brightness/ Contrast : MAX;
Audio Output (400 Hz) : 1/8 of Maximum Audio Output (10W + 10W) ;
VOL = 29
AC Input: 99VAC ~ 264VAC 50Hz
Wake UP LAN : Off
Model
4T-C60AH1X
Power Consumption
Specification (IEC600657)
Standard
Value
Limit
Value
Power Consumption 185 W +10%
Power Consumption at
Stand-by Operating
0.6 W 0.6W
6. SOFTWARE VERSION
Confirmation on Software version will be done during meeting.
Model Software Package
4T-C60AH1X
Fox2_Asia_Pack02_XXXX.IMG
Main Software Filename : XXXX is Software version
If any changes of software, will be informed by MARUHEN