CHAPTER 1. PRODUCT SPECIFICATION
[1] SPECIFICATION
INDOOR UNIT
AH-MP20
High 44
Mid. 37
Low 35
High
17.5
Med. 13.4
Lo
w 11.9
Cross flow fan
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid 1/2" , 1/4"
mm O.D 20
Width 1040 (1155)
Height 325 (300)
Depth 220 (385)
19 (21)
2
(at cooling)
m3/min.
dB(A)
Noise level
(at cooling)
Fan system
dB(A) 53
dB(A)
Net weight kg 55 (59)
Air filters Polypropylene net (Washable)
Net dimensions mm 890 (1020)
mm 645 (735)
mm 327 (398)
Safety device Compressor : Internal protector
Fan motor : Thermal protector(Internal)
Fuse, Micro computer control
Fan Propeller fan
Connections
Drive Direct drive
m3/min.
44
m3/min.
Air flow quantity
Refrigerant system Evaporator Louver fin and Grooved tube type
Condenser Louver fin and Grooved tube type
Control Capillary tube
Refrigerant volume R22 1300g
Power factor % 92 - 98
Compressor Type Hermetically sealed rotary type
Model PH31VNET
Oil charge 670cc ,DIAMOND MS32(N-1)
A 7.9
Rated input * W 1720
50
Rated voltage V 220
Phase Single
Electrical data
OUTDOOR UNIT
AU-MP20
Cooling capacity kW 5.30
Drain piping
Others
1. AH-MP20 / AU-MP20
ITEMS
Moisture removal Liters/h
Rated frequency Hz
Rated current
φ