Check the following points before call-
ing for service.
The unit does not operate
Check if the circuit breaker has tripped or the
fuse has blown.
The unit does not cool effectively
Check the lters. If dirty, clean them.
Check the outdoor unit to make sure nothing
is blocking the air inlet or outlet.
Check the thermostat is proper setting.
Make sure windows and doors are closed
tightly.
The unit does not receive the remote
control signal
Check whether the remote control batteries
have become old and weak.
Try to send the signal again with the remote
control pointed properly towards the unit’s
signal receiver window.
Check whether the remote control batteries
are installed properly.
Please call for service when the green
OPERATION lamp, the orange TIMER
lamp and the blue PLASMACLUSTER
lamp on the unit blink.
To describe the malfunction to service,
you may nd out the error code by the
remote control before calling for ser-
vice.
BEFORE CALLING FOR SERVICE
The following conditions do not denote
equipment malfunctions.
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on im-
mediately after it is turned off. The unit will not
operate immediately after the mode is changed.
This is to protect the unit. Wait 3 minutes before
operating the unit.
ODORS
Carpet and furniture odors that entered into the
unit may be sent out from the unit.
CRACKING NOISE
This sound is generated by the friction of the
unit expanding or contracting due to a tempera-
ture change.
MIST SEEN AT INDOOR AIR OUTLET
In cooling operation, this is caused by the differ-
ence between the room air temperature and the
air discharged.
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit
will rotate its fan for about a minute to cool
down the unit.
SWISHING NOISE
The soft, swishing noise is the sound of the
refrigerant owing inside the unit.
(For Premium models only)
ODOR EMITTED FROM THE
PLASMACLUSTER AIR OUTLET
This is the smell of ozone generated from
the Plasmacluster Ion generator. The ozone
concentration is very small, posing no adverse
effect on your health. The ozone discharged
into the air rapidly decomposes, and its density
in the room will not increase.
A LOW BUZZING NOISE
This is a sound of the unit generating Plasma-
cluster ions.
BEFORE CALLING FOR SERVICE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AH-XP10UXD and is the answer not in the manual?

Sharp AH-XP10UXD Specifications

General IconGeneral
BrandSharp
ModelAH-XP10UXD
CategoryAir Conditioner
LanguageEnglish