Main Sub
Item Content
Adjustment
code code range
27 03 Sets
PC/Modem ID
number.
SIMULATION NO.27- 3
PC/MODEM ID NUMBER SETTING
PC/MODEM CURRENT ID NUMBER
XXXXXXXXXX
[PAUSE]KEY:END DISPLAY
[Content] The ID numbers of the PPC and PC/Modem in the PPC communication system
can be set.
Select which ID number you want to set, one for the PPC or one for the
PC/Modem.The screen displays the current ID number setting. If you want to
change the setting, press the [1] key to display the ID number input screen. Enter
a new ID number. Press the [PRINT] key to register the entered ID number in the
PC/Modem.
If the PC/Modem are not connected when the current setting of the PC/Modem is
read, the “U7-00” trouble occurs.
(a) Operation/display
[PRINT]: If the entered value is valid, the current setting is updated and the screen
changes to the next one.
If the entered value is not valid, the input field is cleared and the error
buzzer sounds.
[0-9]: Enters new settings.
[C]: Clears the input field.
[PAUSE]: No setting is made and the sub code input screen is displayed.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
04 Sets start/end
of service.
SIMULATION NO.27- 4
PPC SERVICE START/END SETTING
1.PPC SERVICE START SETTING
2.PPC SERVICE END SETTING
SELECT WITH TEN KEY
• When “1” is selected:
SIMULATION NO.27- 4
PPC SERVICE START/END SETTING
PPC SERVICE START SETUP HAS COMPLETED
[PAUSE]KEY:END DISPLAY
• When “2” is selected:
SIMULATION NO.27- 4
PPC SERVICE START/END SETTING
PPC SERVICE END SETUP HAS COMPLETED
[PAUSE]KEY:END DISPLAY
9 – 54